product listing

Rosemount Transmitters

Yokogawa Transmitters

E+H Transmitters

ABB

Siemens

Sick Sensors

Keyence Sensors

Schncider

Festo Sensors

Pilz sensors

Euchner Switch

+GF+

Foxboro

Honeywell

Bently Nevada Sensors

BECKHOFF

MEAN WELL power supply

IFM SENSORS

BAUMER Sensors

wenglor Sensors

FESTO

Rexroth

MOOG

Products

Home>Products>Rosemount Transmitters

Rosemount 3051SFC Compact Conditioning Orifice Plate Flow Meter
Rosemount  3051SFC Compact Conditioning Orifice Plate Flow Meter
Describe
Rosemount  3051SFC Compact Conditioning Orifice Plate Flow Meter

The Rosemount 3051SFC Compact Conditioning Orifice Plate Flow Meter is a no-equal solution for multivariable measurement, obtaining direct variable measurements in combinations of differential pressure, static pressure and process temperature. This flow meter comes with a patented, 4-hole conditioning orifice plate for accurate measurement in turbulent flow conditions. This orifice plate also reduces pipe straight run, requiring only two pipe diameters (2D) upstream and downstream of the plate.


Specifications

DOWNLOAD FULL SPECS
Measurement Type Differential Pressure, Static Pressure, Process Temperature
 Differential Pressure and Static Pressure
 Differential Pressure and Process Temperature
 Differential Pressure
Accuracy 0.40 Beta: ±0.75% of flow rate
0.50 & 0.65 Beta: ±1.15% of flow rate
Stability Up to ±0.15% of Upper Range Limit (URL) for 15 years
Warranty Up to 15-year limited warranty
Rangedown Up to 200:1 (14:1 flow turndown)
Measurement Range Up to 2000 psi (137,89 bar) differential, Up to 3626 psia (250,00 bar) absolute, Up to 3626 psig (250,00 bar) gage
Line Size 2 to 12 in. (50 to 300 mm)
Output Differential pressure, static pressure, process temperature, scaled variable, mass flow, volumetric flow, energy flow
Communication Protocol 4-20 mA HART?, WirelessHART?, FOUNDATION? Fieldbus
Process Wetted Material 316 SST
Diagnostics Basic Diagnostics, Power Advisory Diagnostics, Advanced Diagnostics
Certifications/Approvals SIL 2/3 certified to IEC 61508 by an independent 3rd party, NACE, hazardous location, see full specs for complete list of certifications





Features

Designed with built-in flow calculations for direct reporting of fully-compensated mass flow
Patented 4-hole orifice plate design enables accurate flow measurement in turbulent flow profiles
Innovative orifice plate requires only 2D upstream and downstream to reduce pipe straight-run requirements
Advanced diagnostics provide diagnostic coverage to detect abnormal process conditions and electrical loop issues
Callendar-Van Dusen sensor matching improves temperature accuracy enabling best-in-class flow calculations
Ultra for Flow performance class enables optimized flow measurement with a ±0.04% of reading accuracy
All-welded, SuperModule? design offers industry-leading accuracy in harsh environments and applications
Flowmeters come fully configured, leak-tested and ready to install right out of the box for fast installation
Self-centering mechanisms of orifice plate simplify installation and ensure optimal flow measurement accuracy
Orifice plate does not require impulse lines, special flanges or piping modifications for cost-saving efficiency
SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations