product listing
Products
Describe
The Signet 2750 pH/ORP Sensor Electronics featuring
the DryLoc® connector, provides a variety of functions to
suit various requirements.
The 2750 has a preamplified signal and features two
different outputs: a two-wire 4 to 20 mA loop output
with EasyCal function or a digital (S 3 L) output which
allows for longer cable lengths and is compatible with
the Signet 8900 or 9900 instruments, and Profibus
Concentrator.
The 2750 self-configures for pH or ORP operation via
automatic recognition of the electrode type.
The optional EasyCal feature allows simple push-button
calibration and includes an LED indicator for visual
feedback.
The DryLoc electrode connector quickly forms a robust
assembly for submersible and in-line installations.
NEMA 4X junction enclosures are integral parts of
the 2750 in-line version and are also available as
accessories for the submersible 2750.
The 2750 submersible preamplifier can also be used as
an in-line preamplifier when used with the 3/4” or 1”
threaded sensors including the 2724, 2734, 2774 and
2764 series electrodes. The 2750 In-line preamplifier
can be used with Signet fittings up to DN100 (4 in.) and
wet-tap assemblies.
Applications
• Water and Wastewater Treatment
• Neutralization Systems
• Scrubber Control
• Effl uent Monitoring
• Surface Finishing
• Flocculent Coagulation
• Heavy Metal Removal and Recovery
• Toxic Destruction
• Sanitization Systems
• Pool & Spa Control
• Aquatic Animal Life Support Systems
Ordering info:
In-line Sensor Electronics (Yellow body)
3-2750-1 159 000 744 Recommended for 8900 or 9900 instruments
3-2750-2 159 000 745 with EasyCal, recommended for 4 to 20 mA use
3-2750-7 159 001 671 with 4.6 m (15 ft) cable, ¾ in. NPT threads
3-2750-8 Special Order with 4.6 m (15 ft) cable, ISO 7/1R 3/4 threads
Submersible Sensor Electronics (Gray body)
3-2750-3 159 000 746 with 4.6 m (15 ft) cable and ¾ in. NPT threads
3-2750-4 159 000 842 with 4.6 m (15 ft) cable and ISO 7/1R 3/4 threads
Accessories and Replacement Parts
Mfr. Part No. |
Code |
Description |
Calibration |
|
|
3-2700.395 |
159 001 605 |
Calibration kit: includes 3 polyproplyene cups, box used as cup stand, 1 pint pH 4.01, |
|
|
1 pint pH 7.00 |
3822-7115 |
159 001 606 |
20 gm bottle quinhydrone for ORP calibration |
|
|
(must use pH 4.01 and/or pH 7.00 buffer solutions) |
3-2759 |
159 000 762 |
pH/ORP system tester (adapter cable sold separately) |
3-2759.391 |
159 000 764 |
2759 adapter cable for use with 2750 DryLoc sensor electronics |
3-0700.390 |
198 864 403 |
pH buffer kit (1 each 4, 7, 10 pH buffer in powder form, makes 50 ml of each) |
3822-7004 |
159 001 581 |
pH 4 buffer solution, 1 pint (473 ml) bottle |
3822-7007 |
159 001 582 |
pH 7 buffer solution, 1 pint (473 ml) bottle |
3822-7010 |
159 001 583 |
pH 10 buffer solution, 1 pint (473 ml) bottle |
Mounting |
|
|
3-8050.390-1 |
159 001 702 |
Retaining nut replacement kit, Valox K4530 |
3-8050-1 |
159 000 753 |
Universal mount junction box |
3-8050-2 |
159 000 754 |
Universal mount junction box w/EasyCal, use with 3-2750-1, -3, -4, -7 where |
|
|
4 to 20 mA is required |
3-8052-1 |
159 000 755 |
¾ inch NPT mount junction box for cable extension |
3-8052-2 |
159 000 756 |
¾ inch NPT mount junction box w/EasyCal. use with 3-2750-1, -3, -4, -7 where 4 to 20 mA |
|
|
is required |
3-9000.392-1 |
159 000 839 |
Liquid tight connector kit, NPT (1 connector) |
3-9000.392-2 |
159 000 841 |
Liquid tight connector kit, PG 13.5 (1 connector) |
Other |
|
|
5523-0322 |
159 000 761 |
Sensor cable (per ft), 3-cond. plus shield, 22 AWG, black/red/white |
|
|
(for use with 2750) |
3-0252 |
159 001 808 |
Configuration Tool |