product listing
Products
Home>Products>Rosemount Transmitters
Describe
Rosemount 3051CFP Integral Orifice Flow Meter
Designed with an integral orifice primary element for easy installation, the Rosemount 3051CFP Integral Orifice Flow Meter is an industry-leading flow measurement solution. This flow meter utilizes a self-centering integral orifice plate that is provided in a meter run and engineered to facilitate highly accurate flow measurement in small line sizes (0.5 - 1.5 in. or 15 - 40 mm). This flow meter is also leak-tested and calibrated to reduce leak points and increase process control.
Specifications
DOWNLOAD FULL SPECS
Measurement Type Differential Pressure
Accuracy Up to ±1.75% of flow rate
Stability Up to ±0.20% of Upper Range Limit (URL) for 10 years
Warranty Up to 5-year limited warranty
Rangedown Up to 150:1 (8:1 flow turndown)
Measurement Range Up to 1000 inH2O (2,48 bar) differential
Line Size 0.5 to 1.5 in. (15 to 40 mm)
Output Differential pressure, scaled variable
Communication Protocol 4-20 mA HART?, WirelessHART?, FOUNDATION? Fieldbus, PROFIBUS?, 1-5 V Low Power HART?
Process Wetted Material 316 SST
Diagnostics Power Advisory Diagnostics, Advanced Diagnostics
Certifications/Approvals SIL 2/3 certified to IEC 61508 by an independent 3rd party, NACE?, hazardous location, see full specs for complete list of certifications
Features
Complete flow assemblies are leak-tested and calibrated to reduce leak points up to 70% and simplify installation
Primary element integrated in a meter run for ease of installation
Orifice plate suitable for small line sizes 0.5- 1.5 in. (15 - 40 mm) for flow measurement accuracy and repeatability
10-year stability and 8:1 flow turndown (150:1 rangedown) produce reliable measurements and application flexibility
Local operator interface offers easy-to-use menus and built-in configuration buttons for streamlined commissioning
Power advisory diagnostics detect electrical loop integrity issues for reduced downtime
SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
Designed with an integral orifice primary element for easy installation, the Rosemount 3051CFP Integral Orifice Flow Meter is an industry-leading flow measurement solution. This flow meter utilizes a self-centering integral orifice plate that is provided in a meter run and engineered to facilitate highly accurate flow measurement in small line sizes (0.5 - 1.5 in. or 15 - 40 mm). This flow meter is also leak-tested and calibrated to reduce leak points and increase process control.
Specifications
DOWNLOAD FULL SPECS
Measurement Type Differential Pressure
Accuracy Up to ±1.75% of flow rate
Stability Up to ±0.20% of Upper Range Limit (URL) for 10 years
Warranty Up to 5-year limited warranty
Rangedown Up to 150:1 (8:1 flow turndown)
Measurement Range Up to 1000 inH2O (2,48 bar) differential
Line Size 0.5 to 1.5 in. (15 to 40 mm)
Output Differential pressure, scaled variable
Communication Protocol 4-20 mA HART?, WirelessHART?, FOUNDATION? Fieldbus, PROFIBUS?, 1-5 V Low Power HART?
Process Wetted Material 316 SST
Diagnostics Power Advisory Diagnostics, Advanced Diagnostics
Certifications/Approvals SIL 2/3 certified to IEC 61508 by an independent 3rd party, NACE?, hazardous location, see full specs for complete list of certifications
Features
Complete flow assemblies are leak-tested and calibrated to reduce leak points up to 70% and simplify installation
Primary element integrated in a meter run for ease of installation
Orifice plate suitable for small line sizes 0.5- 1.5 in. (15 - 40 mm) for flow measurement accuracy and repeatability
10-year stability and 8:1 flow turndown (150:1 rangedown) produce reliable measurements and application flexibility
Local operator interface offers easy-to-use menus and built-in configuration buttons for streamlined commissioning
Power advisory diagnostics detect electrical loop integrity issues for reduced downtime
SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations