product listing

Rosemount Transmitters

Yokogawa Transmitters

E+H Transmitters

ABB

Siemens

Sick Sensors

Keyence Sensors

Schncider

Festo Sensors

Pilz sensors

Euchner Switch

+GF+

Foxboro

Honeywell

Bently Nevada Sensors

BECKHOFF

MEAN WELL power supply

IFM SENSORS

BAUMER Sensors

wenglor Sensors

FESTO

Rexroth

MOOG

Products

Home>Products>Rosemount Transmitters

Rosemount 3051CFC Wireless Compact Conditioning Orifice Plate Flow Meter
Rosemount  3051CFC Wireless Compact Conditioning Orifice Plate Flow Meter
Describe
Rosemount  3051CFC Wireless Compact Conditioning Orifice Plate Flow Meter

The Rosemount 3051CFC Wireless Compact Conditioning Orifice Plate Flow Meter is an industry-leading flow measurement solution featuring >99% data reliability delivered via a secure WirelessHART? network. This device includes a compact orifice plate with a patented, 4-hole design that offers accurate measurement in turbulent flow conditions. This conditioning orifice plate reduces pipe straight run, requiring only two pipe diameters (2D) upstream and downstream.


Specifications

DOWNLOAD FULL SPECS
Measurement Type Differential Pressure
Accuracy Up to ±1.95% of flow rate
Stability Up to ±0.20% of Upper Range Limit (URL) for 10 years
Warranty Up to 5-year limited warranty
Rangedown Up to 150:1 (8:1 flow turndown)
Measurement Range Up to 1000 inH2O (2,48 bar) differential
Line Size 2 to 12 in. (50 to 300 mm)
Output Differential pressure, scaled variable
Communication Protocol WirelessHART?
Process Wetted Material 316 SST
Diagnostics Basic Diagnostics
Certifications/Approvals NACE?, hazardous location, see full specs for complete list of certifications
Update Rate 2 sec. to 60 min., user selectable
Power Module Life Up to 10-year life, field replaceable (order separately)
Wireless Range Internal antenna (225 m)



Features

WirelessHART? technology is secure, cost-effective and delivers >99% data reliability
10-year stability and 8:1 flow turndown (150:1 rangedown) produce reliable measurements and application flexibility
Patented 4-hole orifice plate design enables accurate flow measurement near upstream flow disturbances.
Complete flow assemblies are leak-tested and calibrated to reduce leak points up to 70% and simplify installation
Innovative orifice plate requires only 2D upstream and downstream to reduce pipe straight-run requirements SmartPower? module provides up to 10-year maintenance-free operation and field replacement without transmitter removal
Easy installation enables quick instrumentation of measurement points without the cost of wiring